SYNC VOLTAGES

model

Measured sync

model

Measured sync

Ascor ® QC8

24. V

Norman ®  P500-M

30.00 V

Ascor ® portrait 400

7.0 V

Norman ® P2000-D

92.00 V

Bowens ® 750

14.5 V

Norman ® SL-800

14.20 V

Bowens ® Esprit 500

15.0 V

Novatron ® 440 HDX

9.50 V

Bowens ® monolite800 CX

207. V

Novatron ® V-400D

5.70 V

Bowens ® mono Bronze

28. V

Novatron ®  M500

5.75 V

Bowens ® mono silver plus

28. V

Novatron ® V600

11.00 V

Bowens Prolite 60 , 82 , 100 ®

14.5 V

OPUS ® OPL-K250

8.30 V

Broncolor ® Impact 41

8.8 V

Photogenic ® AA01A solid state trigger

10.60 V

Courtenay Solaflash 600 ®

11.65 V

Photogenic ® PL1250

11.50 V

Courtenay Solaflash 1250 ®

15.50 V

Photogenic ® PL1500-PS

11.50 V

Dyna-lite ® M500X

8.30 V

Photogenic ® PL2500 DR

10.20 V

Dyna-lite ® M800E

8.80 V

Speedotron ® 812

80.0 V

Dyna-lite ® M1000E

9.40 V

Speedotron ® 1205CX

58.0 V

Dyna-lite ® uni-400jr

9.60 V

Speedotron ® 2401 A

75.0 V

Elinchrom ® 250 / 500

11.70 V

Speedotron ® 2403 CX

80.0 V

Multiblitz ® Profilite compact 200

8.50 V

Speedotron ® 2403 CX LV

16.0 V

Norman ® P400-D

100.00 V

Speedotron ® 4803

68.0 V